The following is an explanation of the Underwriter’s Laboratories’ fire resistant container testing procedures on the Class 350°F, one hour and Class 350°F two hour Fire Labels.

U.L. Label/Class 350°F-one hour and Class 350°F-two hour. The safe will maintain an interior temperature less than 350°F when exposed to fire for a period of one hour at 1700°F or for a period of two hours at 1850°F. Safe must successfully undergo all other requirements for the Fire Endurance Test, Explosion Hazard Test and the Fire/Impact Test as stated below.

Fire Endurance Test

After heat sensors and paper are placed inside the safe, the unit is locked and exposed to a uniformly distributed fire. The furnace is regulated to reach a maximum temperature of 1700°F for a period of one hour, or 1850°F for two hours, then allowed to cool without opening the furnace. The interior temperature is recorded throughout the test and during the cooling period until a definite drop is shown and must never exceed 350°F.

Once cooled, the unit is opened and examined for usability. The units locking mechanisms and parts fastenings are examined for security and the interior examined for visible evidence of undue heat transmis

Explosion Hazard Test

The safe is locked and placed into a furnace preheated to 2000°F. This temperature is maintained for 30 minutes (2 hour test is 45 minutes) and if no explosion results, the unit is allowed to cool without opening the furnace doors. Once cooled, the unit is opened and examined for usability. The units locking mechanisms and parts fastenings are examined for security and the interior examined for visible evidence of undue heat transmission.

Fire Impact Test (Manufacturer’s Option)

After the explosion hazard test the safe is removed from the furnace and within two minutes is dropped 30' onto a riprap of brick on a heavy concrete base. After impact the unit is examined for deformation, rupture of parts, damaged insulation and any other openings into the interior of the unit. Once cooled, the unit is inverted and reheated to 1550°F for a period of 30 min. (2 hour test: 45 min. at 1638°F).

Once cooled, the unit is opened and examined for usability. The units locking mechanisms and parts fastenings are examined for security and the interior examined for visible evidence of undue heat transmission.

We are here for you.
"Don't Struggle with The Burglary Safes, Call Our Experts"

781-933-9999

AMSEC

We Sell and Service all types of Safes including Gardall, Amsec, Sentry, and Brinks

 

Local Locksmith

Looking for A Locksmith Near You?! Let Our Professionals Take.

House Lockout

Our 100% licensed team has the expertise and the experience.

Lock Rekey

Our expert professionals can solve the problem for you.

Lock Installation

Trust us Locksmith Inc. to protect your home and business.

Gate Lock Repair

Our lock repair services of homes allow you to have the professionals right by your side.
gardall

Our Services

"Don't Struggle with a Safe Lockout, Call Our Experts"


LOCKSMITH SERVICES SINCE 1977

Coupons

Our professionals analyze the lock system and create the keys that provide top-quality safety and comfortable functionality for you.

$ 10 OFF

Transponder "Chip" Keys And Remotes Over $50.00

 

TCHIP10OFF

$ 10 OFF

Any Service Call
(1st Time Customers Only)

 

CALREF10OFF

$ 20 OFF

Any Service Call Over
$200.00 (1st Time Customers Only)

 

SPEPLUS20OFF

FREE

Free "Cylinder Guard" Installed On
Any Storefront Door Service/per Service

 

CYGUFREE

FREE

Free Peep Hole Installed
With Any Service Call

 

PEHOFREE